Kejbil tal-Fibra Ottika ta' Barra b'Modalità Unika SM G652D GYTA 24 fibra b'Difna Diretta
Dejta Teknika tal-Kejbil GYTA
| Tip ta' kejbil | Għadd ta' Fibri | Tubi | Mili | Dijametru tal-kejbil mm | Piż tal-Kejbil kg/km | Saħħa tat-Tensile Terminu Twil/Qasir N | Reżistenza għat-Tgħaffiġ Terminu Twil/Qasir N/100mm | Raġġ tal-Liwi Statiku mm |
| GYTA-2~12 | 8~12 | 1 | 4 | 9.0 | 100 | 1000/3000 | 1000/3000 | 10D/20D |
| GYTA-14~18 | 14~18 | 3 | 2 | 9.0 | 100 | 1000/3000 | 1000/3000 | 10D/20D |
| GYTA-20~24 | 20~24 | 4 | 1 | 9.5 | 110 | 1000/3000 | 1000/3000 | 10D/20D |
| GYTA-26~36 | 26~36 | 4 | 1 | 9.5 | 120 | 1000/3000 | 1000/3000 | 10D/20D |
| GYTA-38~48 | 38~48 | 4 | 1 | 10.0 | 140 | 1000/3000 | 1000/3000 | 10D/20D |
| GYTA-50~60 | 50~60 | 5 | 0 | 10.8 | 150 | 1000/3000 | 1000/3000 | 10D/20D |
| GYTA-62~72 | 62~72 | 6 | 0 | 11.9 | 170 | 1000/3000 | 1000/3000 | 10D/20D |
| GYTA-74~84 | 74~84 | 7 | 1 | 12.5 | 180 | 1000/3000 | 1000/3000 | 10D/20D |
| GYTA-86~96 | 86~96 | 8 | 0 | 13.6 | 210 | 1000/3000 | 1000/3000 | 10D/20D |
| GYTA-98~108 | 98~108 | 9 | 1 | 14.5 | 230 | 1000/3000 | 1000/3000 | 10D/20D |
| GYTA-110~120 | 110~120 | 10 | 0 | 14.8 | 240 | 1000/3000 | 1000/3000 | 10D/20D |
| GYTS-122~144 | 122~132 | 11 | 1 | 15.4 | 260 | 1000/3000 | 1000/3000 | 10D/20D |
| GYTA-146~216 | 146~216 | 12 | 0 | 19.8 | 395 | 1000/3000 | 1000/3000 | 10D/20D |
| GYTA-218~288 | 218~288 | 12 | 0 | 20.8 | 470 | 1000/3000 | 1000/3000 | 10D/20D |
Karatteristika tal-fibra:
| Stil tal-fibra | Unità | SM G652D | SM G657A | MM 50/125 | MM 62.5/125 | MM OM3-300 | MM OM4-550 | |
| Kundizzjoni | nm | 1310/1550 | 1310/625 | 850/1300 | 850/1300 | 850/1300 | 850/1300 | |
| Attenwazzjoni | dB/km | ≤0.34/0.22 | ≤.035/0.21 | ≤3.0/1.0 | ≤3.0/1.0 | ≤3.0/1.0 | ≤3.5/2.2 | |
| Tixrid | 1550nm | Ps/(nm*km) | ≤18 | ≤18 | ---- | ---- | ---- | ---- |
| 1625nm | Ps/(nm*km) | ≤22 | ≤22 | ---- | ---- | ---- | ---- | |
| Wisa' tal-banda | 850nm | MHZ.KM | ---- | ≥400 | ≥160 | |||
| 1300nm | MHZ.KM | ---- | ≥800 | ≥500 | ||||
| Tul ta' mewġa ta' dispersjoni żero | nm | ≥1302 ≤1322 | ≥1302 ≤1322 | ---- | ---- | ≥ 1295, ≤1320 | ≥ 1295, ≤1340 | |
| Inklinazzjoni ta' dispersjoni żero | nm | ≤0.091 | ≤0.090 | ---- | ---- | ---- | ---- | |
| Fibra Individwali Massima PMD | ≤0.2 | ≤0.2 | ---- | ---- | ≤0.11 | |||
| Valur tal-Link tad-Disinn tal-PMD | Ps(nm2*km) | ≤0.08 | ≤0.1 | ---- | ---- | ---- | ---- | |
| Tul ta' mewġa tal-qtugħ tal-fibra λc | nm | ≥1180 ≤1330 | ≥1180 ≤1330 | ---- | ---- | ---- | ---- | |
| Qtugħ tal-kejbil tul ta' mewġa λcc | nm | ≤1260 | ≤1260 | ---- | ---- | ---- | ---- | |
| MFD | 1310nm | um | 9.2±0.4 | 9.0±0.4 | ---- | ---- | ---- | ---- |
| 1550nm | um | 10.4±0.8 | 10.1±0.5 | ---- | ---- | ---- | ---- | |
| Numeriku Apertura (NA) | ---- | ---- | 0.200± 0.015 | 0.275± 0.015 | 0.200± 0.015 | 0.200± 0.015 | ||
| Pass (medja ta' bidirezzjonali kejl) | dB | ≤0.05 | ≤0.05 | ≤0.10 | ≤0.10 | ≤0.10 | ≤0.10 | |
| Irregolaritajiet fuq it-tul u l-punt tal-fibra | dB | ≤0.05 | ≤0.05 | ≤0.10 | ≤0.10 | ≤0.10 | ≤0.10 | |
| Tixrid lura tad-differenza koeffiċjent | dB/km | ≤0.03 | ≤0.03 | ≤0.08 | ≤0.10 | ≤0.08 | ≤0.08 | |
| Uniformità tal-attenwazzjoni | dB/km | ≤0.01 | ≤0.01 | |||||
| Dijametru tal-qalba | um | 9 | 9 | 50±1.0 | 62.5±2.5 | 50±1.0 | 50±1.0 | |
| Dijametru tal-kisi | um | 125.0±0.1 | 125.0±0.1 | 125.0±0.1 | 125.0±0.1 | 125.0±0.1 | 125.0±0.1 | |
| Kisi mhux ċirkolari | % | ≤1.0 | ≤1.0 | ≤1.0 | ≤1.0 | ≤1.0 | ≤1.0 | |
| Dijametru tal-kisi | um | 242±7 | 242±7 | 242±7 | 242±7 | 242±7 | 242±7 | |
| Kisi/spunża żball konċentriku | um | ≤12.0 | ≤12.0 | ≤12.0 | ≤12.0 | ≤12.0 | ≤12.0 | |
| Kisi mhux ċirkolari | % | ≤6.0 | ≤6.0 | ≤6.0 | ≤6.0 | ≤6.0 | ≤6.0 | |
| Żball fil-konċentriċità tal-qalba/kisi | um | ≤0.6 | ≤0.6 | ≤1.5 | ≤1.5 | ≤1.5 | ≤1.5 | |
| Curl(raġġ) | um | ≤4 | ≤4 | ---- | ---- | ---- | ---- | |
Kulur tal-fibra:
| 1 | 2 | 3 | 4 | 5 | 6 |
| Blu | Oranġjo | Aħdar | Kannella | Griż | Abjad |
| 7 | 8 | 9 | 10 | 11 | 12 |
| Aħmar | Iswed | Isfar | Vjola | Roża | Akkwa |
Deskrizzjoni tal-Kejbil GYTA
+ Il-fibri, 250μm, huma pożizzjonati f'tubu maħlul magħmul minn plastik b'modulu għoli.
+ It-tubi huma mimlija b'kompost tal-mili reżistenti għall-ilma.
+ Wajer tal-azzar, xi kultant miksi bil-polietilene (PE) għal kejbil b'għadd għoli ta' fibra, jinsab fiċ-ċentru tal-qalba bħala membru ta' saħħa metalliku.
+ It-tubi (u l-mili) huma mibrumin madwar il-membru tas-saħħa f'qalba tal-kejbil kompatta u ċirkolari.
+ AnLaminat tal-Polietilene tal-Aluminju (APL)jiġi applikat madwar il-qalba tal-kejbil, li timtela bil-kompost tal-mili biex tipproteġiha mid-dħul tal-ilma.
+ Il-kejbil huwa komplut b'kisja tal-PE.
Kostruzzjoni:
Karatteristiċi tal-Kejbil GYTA:
+ Prestazzjoni mekkanika u tat-temperatura tajba
+ Tubu maħlul ta' saħħa għolja li huwa reżistenti għall-idroliżi
+ Kompost speċjali għall-mili tat-tubi jiżgura protezzjoni kritika tal-fibra
+ Struttura kompatta ddisinjata apposta hija tajba biex tipprevjeni li t-tubi maħlula jiċkienu
+ Il-kisja tal-PE tipproteġi l-kejbil mir-radjazzjoni ultravjola
+ Ittieħdu l-miżuri li ġejjin biex jiġi żgurat li l-kejbil ma jidħolx ilma minnu:
+ Wajer tal-azzar użat bħala l-membru ċentrali tas-saħħa
+ Kompost għall-mili ta' tubi sfużi
+ 100% mili tal-qalba tal-kejbil
+ 100% ittestjat qabel il-ġarr.
+ Tul tar-rukkell tal-kejbil: 1km, 2km, 3km, 5km
Applikazzjoni tal-Kejbil GYTA:
+ Adottat għad-distribuzzjoni fuq barra.
+ Adattat għat-tqegħid ta' pajpijiet, difna diretta, metodu taħt l-art.
+ Komunikazzjoni fuq distanza twila u netwerk lokali.
Ippakkjar: