Kejbil tal-Fibra Ottika ta' Barra minn Modalità Unika ta' Tubu Sfuż Ċentrali GYXTW mill-Ajru
Karatteristika Mekkanika tal-Kejbil tal-Fibra Ottika GYXTW:
| Kejbil GYXTW | Dijametru tal-kejbil | Piż |
| Għadd ta' fibri: minn 2 fibri sa 24 fibra | 8.0mm + -0.5mm | 70kg/km |
| 7.0mm + -0.3mm | 50kg/km | |
| Firxa tat-temperatura | -40°Ċ+70°Ċ | |
| Raġġ minimu tal-liwi (mm) | Terminu twil | 10D |
| Liwi MinimuRaġġ (mm) | Terminu qasir | 20D |
| Saħħa Tensili Minima Permissibbli (N) | Terminu twil | 1200 |
| Saħħa Tensili Minima Permissibbli (N) | Terminu qasir | 1500 |
| Temperatura tat-tħaddim | -40°Ċ+70°Ċ | |
| Temperatura tal-installazzjoni | -20°Ċ+60°Ċ | |
| Temperatura tal-ħażna | -40°Ċ+70°Ċ | |
Karatteristika tal-fibra:
| Stil tal-fibra | Unità | SM G652D | SM G657A | MM 50/125 | MM 62.5/125 | MM OM3-300 | MM OM4-550 | |
| Kundizzjoni | nm | 1310/1550 | 1310/625 | 850/1300 | 850/1300 | 850/1300 | 850/1300 | |
| Attenwazzjoni | dB/km | ≤0.34/0.22 | ≤.035/0.21 | ≤3.0/1.0 | ≤3.0/1.0 | ≤3.0/1.0 | ≤3.5/2.2 | |
| Tixrid | 1550nm | Ps/(nm*km) | ≤18 | ≤18 | ---- | ---- | ---- | ---- |
| 1625nm | Ps/(nm*km) | ≤22 | ≤22 | ---- | ---- | ---- | ---- | |
| Wisa' tal-banda | 850nm | MHZ.KM | ---- | ≥400 | ≥160 | |||
| 1300nm | MHZ.KM | ---- | ≥800 | ≥500 | ||||
| Tul ta' mewġa ta' dispersjoni żero | nm | ≥1302 ≤1322 | ≥1302 ≤1322 | ---- | ---- | ≥ 1295, ≤1320 | ≥ 1295, ≤1340 | |
| Inklinazzjoni ta' dispersjoni żero | nm | ≤0.091 | ≤0.090 | ---- | ---- | ---- | ---- | |
| Fibra Individwali Massima PMD | ≤0.2 | ≤0.2 | ---- | ---- | ≤0.11 | |||
| Valur tal-Link tad-Disinn tal-PMD | Ps(nm2*km) | ≤0.08 | ≤0.1 | ---- | ---- | ---- | ---- | |
| Tul ta' mewġa tal-qtugħ tal-fibra λc | nm | ≥1180 ≤1330 | ≥1180 ≤1330 | ---- | ---- | ---- | ---- | |
| Qtugħ tal-kejbil tul ta' mewġa λcc | nm | ≤1260 | ≤1260 | ---- | ---- | ---- | ---- | |
| MFD | 1310nm | um | 9.2±0.4 | 9.0±0.4 | ---- | ---- | ---- | ---- |
| 1550nm | um | 10.4±0.8 | 10.1±0.5 | ---- | ---- | ---- | ---- | |
| Numeriku Apertura (NA) | ---- | ---- | 0.200± 0.015 | 0.275± 0.015 | 0.200± 0.015 | 0.200± 0.015 | ||
| Pass (medja ta' bidirezzjonali kejl) | dB | ≤0.05 | ≤0.05 | ≤0.10 | ≤0.10 | ≤0.10 | ≤0.10 | |
| Irregolaritajiet fuq it-tul u l-punt tal-fibra | dB | ≤0.05 | ≤0.05 | ≤0.10 | ≤0.10 | ≤0.10 | ≤0.10 | |
| Tixrid lura tad-differenza koeffiċjent | dB/km | ≤0.03 | ≤0.03 | ≤0.08 | ≤0.10 | ≤0.08 | ≤0.08 | |
| Uniformità tal-attenwazzjoni | dB/km | ≤0.01 | ≤0.01 | |||||
| Dijametru tal-qalba | um | 9 | 9 | 50±1.0 | 62.5±2.5 | 50±1.0 | 50±1.0 | |
| Dijametru tal-kisi | um | 125.0±0.1 | 125.0±0.1 | 125.0±0.1 | 125.0±0.1 | 125.0±0.1 | 125.0±0.1 | |
| Kisi mhux ċirkolari | % | ≤1.0 | ≤1.0 | ≤1.0 | ≤1.0 | ≤1.0 | ≤1.0 | |
| Dijametru tal-kisi | um | 242±7 | 242±7 | 242±7 | 242±7 | 242±7 | 242±7 | |
| Kisi/spunża żball konċentriku | um | ≤12.0 | ≤12.0 | ≤12.0 | ≤12.0 | ≤12.0 | ≤12.0 | |
| Kisi mhux ċirkolari | % | ≤6.0 | ≤6.0 | ≤6.0 | ≤6.0 | ≤6.0 | ≤6.0 | |
| Żball fil-konċentriċità tal-qalba/kisi | um | ≤0.6 | ≤0.6 | ≤1.5 | ≤1.5 | ≤1.5 | ≤1.5 | |
| Curl(raġġ) | um | ≤4 | ≤4 | ---- | ---- | ---- | ---- | |
Kulur tal-fibra:
| 1 | 2 | 3 | 4 | 5 | 6 |
| Blu | Oranġjo | Aħdar | Kannella | Griż | Abjad |
| 7 | 8 | 9 | 10 | 11 | 12 |
| Aħmar | Iswed | Isfar | Vjola | Roża | Akkwa |
X'inhu l-kejbil GYXTW?
•Il-kejbil tal-fibra ottika GYXTW, il-fibri ta' 250μm, huma pożizzjonati f'tubu maħlul magħmul minn plastik b'modulu għoli.
•It-tubi huma mimlija b'kompost tal-mili reżistenti għall-ilma.
•It-tubu huwa mgeżwer b'saff ta' PSP lonġitudinalment.
•Bejn il-PSP u t-tubu loose, jiġi applikat materjal li jimblokka l-ilma biex il-kejbil jinżamm kompatt u ma jgħaddix ilma minnu.
•Żewġ wajers tal-azzar paralleli jitqiegħdu fuq iż-żewġ naħat tat-tejp tal-azzar.
•Il-kejbil huwa kkompletat b'kisja tal-polietilene (PE), ta' kulur iswed, biex tipproteġi l-fibra mill-UV.
Kostruzzjoni:
Karatteristiċi:
•Membru parallel tal-wajer tal-azzar, tejp tal-fibra tal-azzar b'tubu protettiv tal-mili armat.
•Prestazzjoni mekkanika u ambjentali eċċellenti.
•Struttura kompatta, piż ħafif tista' tiġi installata b'mod konvenjenti u mħaddma sempliċement.
•Għażla oħra ta' fibra hija disponibbli: Modalità Unika (G652D, G657A, G657B) u Multimode (OM1, Om2, Om3, OM4, OM5)
•Għadd ta' fibra: 2fo ~ 12fo
•Għażla tad-dijametru: 6.0mm, 7.0mm (ex-work), 8.0mm
Applikazzjoni:
+ Adottat għad-distribuzzjoni fuq barra.
+ Adattat għall-metodu ta' tqegħid ta' pajpijiet mill-ajru.
+ Komunikazzjoni fuq distanza twila u netwerk lokali.
Ippakkjar: